Turbo Pump and Vacuum Pump Repair
Turbo, maglev and roughing pumps rebuilt
Turbo pump repair
We repair turbomolecular pumps, maglev included: bearing replacement, rotor balancing and full rebuilds.
Send yours in when it gets loud, grinds, vibrates, falls short of full speed, runs hot or keeps tripping its controller.
We also rebuild rotary vane, scroll, diffusion, Roots and dry screw pumps.
Pump or controller?
When a turbo pump fails, it is the pump, the controller or both. Send both, and we quote the combination. One quote, one invoice.
- Controller already repaired here? Send the pump the same way.
- Controllers by brand: Turbo Pump Controller Repair
Pumps we rebuild
- Turbomolecular pumps. Pfeiffer HiPace, TMH and TMU; Edwards EXT, STP and nEXT; Leybold TurboVac and MAG; Agilent Varian Turbo-V and TwisTorr; Alcatel/Adixen ATP and ATH; Osaka and Seiko Seiki.
- Maglev turbos. Yes, we take them, including the Leybold MAG and the Edwards STP.
- Oil-sealed rotary vane. Edwards E1M, E2M and RV series; Leybold Trivac D and Trivac B; Pfeiffer DUO and UNO; Alcatel/Adixen 2005 to 2063 and Pascal; Welch DuoSeal; Busch R5.
- Dry scroll. Edwards XDS and nXDS; Agilent IDP and TriScroll; Leybold ScrollVac; Anest Iwata ISP.
- Diffusion. Agilent Varian, Edwards, Leybold, CVC.
- Roots blowers and boosters. Edwards, Leybold, Stokes, Roots, Aerzen, Kinney.
- Dry screw and multi-stage Roots. Edwards iH and GX, Ebara, Kashiyama, Busch COBRA, Hanbell.
Cryopumps and helium compressors: Cryopump and Cryo Compressor Service.
Before you ship a pump
Drain any oil and seal the ports. If the pump saw biological or radioactive material, or ran unusual process gases, tell us before you ship it.